Part No.: SBL03-1
Emergency Stop Button Lockout
a) Made from durable transparent PC.
b) It prohibits access to a switch or control.
c) Horse-show shaped retrpfit base can be used on raised nameplates and off-center installation to accommodate rotary switch knobs.
d) Accommodates buttons up to 50mm diameter and 45mm tall.
e) Fits both 30.5mm and 22 mm diameter switches.
Part NO. | Description |
SBL03-1 | Accepts lock shackles up to 8mm in diameter. |
A dangerous source of energy in a cement plant
Oil (liquid) storage vessel, pipe (liquid) with higher pressure
Place of existence: various reducer fuel tanks, high pressure oil pipes for engineering vehicles, etc
Potential risk: during cutting, welding, disassembly and inspection of high pressure tubing and hydraulic equipment, high pressure oil and liquid suddenly spray and hurt people
Precautions: prior to such work, the following basic safety measures must be taken:
1. Close and lock the valve at the pressure liquid source (or use a blind)
2. Disassemble carefully and pay attention to the standing position. Avoid face and eye disassembly
3. Wear proper eye (face) protective equipment
Compressed gas storage tanks, pipelines (gases)
Location: various compressed gas cylinders, gas storage tanks, pressure pipes, etc
Potential risk: during cutting, welding, disassembly and inspection of the compression vessel, high-pressure gas is suddenly released to hurt people
Precautions: prior to such work, the following basic safety measures must be taken:
1. Close and lock the valve at the source of the pressure vessel (or use a blind plate)
2. Full pressure relief (not only relying on the pressure gauge for judgment)
3. Disassemble carefully and pay attention to the standing position.
4. Wear proper eye (face) protective equipment
5. Pay attention to the damage caused by sudden release of weight of moving materials (such as air compressor desiccant)