Lockey 25mm Steel Shackle Safety Padlock

Lockey 25mm Steel Shackle Safety Padlock
Product Details


Part No.: CP25S

Lockey 25mm Steel Shackle Safety Padlock

  1. PA66 body, vase-style appearance with Lockey patented design, can withstand temperature from -20℃ to +80℃. The steel shackle is chrome plated, withstand temperature from -20℃ to +120℃, ensuring the strength and deformation fracture not easily.

  2. Resistance of chemical, extreme temperatures and UV rays.

  3. Key Retaining Feature: When the shackle is open, the key can’t be removed.

  4. Laser printing and logo engraving available if required.

  5. All different colors selectable.


Part No.

Description

Shackle Material

Specification

KA-P25S

Keyed Alike

 

Steel

 

“KA”: Each padlock is keyed the same in one group

“P”: Straight edge plastic lock body

“S”: Steel shackle

 

Other material can be customized:

“SS”: Stainless steel shackle

“BS”: Brass shackle

KD-P25S

Keyed Differ

MK-P25S

Keyed & Alike/Differ

GMK-P25S

Grand Master Key

KA-P25P

Keyed Alike

 

Nylon

KD-P25P

Keyed Differ

MK-P25P

Keyed & Alike/Differ

GMK-P25P

Grand Master Key


347.jpg

Color Options:

P.jpg


Padlock Body Shape Options:


2018060210193963122991.jpg

Energy isolation and other requirements

Relevant functional departments of the company provide safety locks, locks and "danger" for grassroots units. Do not operate the "TAB" and manage it.

When a crossover job involves the same isolation point, lockout and tagout the isolation point for each job.

Do not lock the screen when cleaning operation, the implementation of single process operation card.

For the follow-up rectification and leakage elimination work items below 1.0mpa, the relevant inspection and maintenance work rules shall be implemented.

During the overhaul of the device, after the overall isolation and replacement of the system, local operations may not be locked, and the corresponding HSE operation plan or inspection and maintenance operation procedures may be implemented.

Violation of graphic

Not isolating all energy sources.

There is no test or the operator is not present during the test.

Operate locked valves and switches.

Unlock and remove labels without authorization.

Keep extra backup keys.


I. accident history

A February morning, a factory maintenance personnel maintenance water source booster pump. Work permit person will stop the pump operation, in the power failure measures, because 380V hand truck type switch operating mechanism card, the switch is not pulled to the "maintenance position", still in the "operation" position. After the licensor and the person in charge of the work confirm it on the spot, after the agreement, hang up the "no closing and no working" sign and start the maintenance work.

During the maintenance, the monitor inspected the switch room and found that the booster pump switch was in the "operation" position. He took down the sign without authorization and tried to open the switch to the "maintenance" position. When pull open close, press "close" button, switch close, have disintegrated booster pump start up a maintenance personnel hurried to dodge, the risk of serious personal injury.

Cause and exposure problems

1. The operator seriously violates the regulations and fails to pull the switch to the "maintenance" position as required by the work ticket. The switch is still in operation

To work;

2. The person in charge of the work seriously violates the rules and regulations, knowing that the switch is still in the "running" position, and has not taken measures to prevent the pump body from suddenly rotating, so he/she agrees to start the work and is not responsible for the members of the work team;

3. The operation monitor seriously violates the rules and regulations and conducts electrical operation without authorization in order to fulfill the procedures of operation ticket.


Feedback